Title :
Towards a portable point-of-use blood analysis with EIS technique device
Author :
Punter-Villagrasa, Jaime ; del Moral-Zamora, Beatriz ; Colomer-Farrarons, Jordi ; Miribel-Catala, P. ; Cid, Joan ; Rodriguez-Villarreal, Ivon ; Prieto-Simon, B.
Author_Institution :
Electron. Dept., Univ. de Barcelona, Barcelona, Spain
Abstract :
In this paper first approach to a compact system for point-of-use primarily blood characteristics analysis by means of an EIS (Electrochemical Impedance Spectroscopy) experience is described. This is based on a custom electronic instrumentation, post processing software and a commercial three electrodes gold sensor. The designed electronic is based on a potentiostat instrumentation supported by a real time platform connected to a remote computer, which allows the instrumentation control, real time monitoring data and its posterior resultant analysis. Moreover, the whole system has been characterized and validated using different sensors and biocompatible materials. The study consists on a complete EIS experience in order to get a full spectrum analysis of impedance behavior in terms of magnitude and phase. As a result, we were able to detect impedance with an average error of less than 3% and a SNR rejection of -40 dB in a frequency working range of 10 Hz to 100 kHz. This integrated approach pushes forward the development of truly autonomous point-of-care devices relying on impedance spectrometry detection.
Keywords :
bioelectric phenomena; biomedical electrodes; biomedical electronics; biomedical telemetry; blood; electrochemical electrodes; electrochemical impedance spectroscopy; electrochemical sensors; gold; medical computing; portable instruments; telemedicine; Au; EIS technique device; SNR rejection; autonomous point-of-care device development; average impedance detection error; biocompatible materials; commercial three electrode gold sensor; compact blood characteristics analysis system; electrochemical impedance spectroscopy; electronic design; electronic instrumentation; frequency 10 Hz to 100 kHz; frequency working range; full spectrum analysis; impedance behavior; impedance magnitude; impedance phase; impedance spectrometry detection; instrumentation control; portable point-of-use blood analysis; post processing software; posterior resultant analysis; potentiostat instrumentation; real time monitoring data; real time platform; remote computer connection; Biology; Biomedical monitoring; Computers; Frequency measurement; Instruments; Monitoring; Signal to noise ratio; Bio-impedance; Blood; Electrochemical Impedance Spectroscopy; Potentiostat;
Conference_Titel :
Multi-Conference on Systems, Signals & Devices (SSD), 2014 11th International
Conference_Location :
Barcelona
DOI :
10.1109/SSD.2014.6808825