DocumentCode :
1360532
Title :
Partial discharge influence on dissipation factor values during stator-bar testing
Author :
Contin, Alfredo ; Zhu, Hugh
Author_Institution :
Dept. of Electr. & Electron. Eng., Univ. of Trieste, Trieste, Italy
Volume :
27
Issue :
6
fYear :
2011
Firstpage :
8
Lastpage :
14
Abstract :
The article investigates how partial discharge activity can influence dissipation factor values in stator-bar testing. In this study, the PD phenomenon was simulated as a process composed of periodic positive and negative bursts of PD pulses over a period T of the applied voltage (frequency = 50 Hz, T 20 ms in this work). These periodic pulses generate a frequency spectrum whose fundamental frequency (50 Hz) can interfere with DF values while DF values are measured at the same frequency. An artificial defect was made on a virgin stator bar to generate PD signals. Both the simulated and real PD signals recorded from the bar at various voltage levels were studied, and the parameters of PD signals that influence the DF values were investigated.
Keywords :
electric machines; machine testing; partial discharge measurement; stators; DF values; PD activity; PD pulses; PD signals; dissipation factor measurements; dissipation factor values; frequency 50 Hz; frequency spectrum; negative bursts; partial discharge activity; partial discharge measurements; periodic positive bursts; stator-bar testing; time 20 ms; Dissipation factors; Frequency measurement; Mathematical model; Partial discharges; Stator windings; dissipation factor; insulation system; partial discharge; stator bar;
fLanguage :
English
Journal_Title :
Electrical Insulation Magazine, IEEE
Publisher :
ieee
ISSN :
0883-7554
Type :
jour
DOI :
10.1109/MEI.2011.6059979
Filename :
6059979
Link To Document :