DocumentCode :
1363385
Title :
A new energy recovery scheme for doubly fed, adjustable-speed induction motor drives
Author :
Liao, Fan ; Sheng, Ji ; Lipo, Thomas A.
Author_Institution :
Dept. of Electr. Eng., Dalian Railway Inst., China
Volume :
27
Issue :
4
fYear :
1991
Firstpage :
728
Lastpage :
733
Abstract :
A new speed control scheme for a wound-rotor induction motor utilizing feedback of the slip power to the stator winding by means of taps is described. It is shown that with this feedback system, the motor can be operated over a very wide range even to slips reaching 0.75. The new concept eliminates the need for a transformer. The selection of feedback point on the stator winding, the equivalent circuit, and the main parameters of this system are discussed. Test results on a wound rotor induction motor are shown, and these indicate that this system also has good performance in addition to its potential for lower cost
Keywords :
induction motors; machine control; stators; variable speed drives; velocity control; adjustable-speed induction motor drives; doubly fed induction motor; energy recovery; equivalent circuit; slip power; speed control; stator winding; wound-rotor induction motor; Circuit testing; Costs; Equivalent circuits; Feedback; Induction motors; Rotors; Stator windings; System testing; Velocity control; Wounds;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/28.85489
Filename :
85489
Link To Document :
بازگشت