Title :
Application of digital signal processing to the detection of partial discharge. Part 2: Optimized A/D conversion
Author :
Shim, I. ; Soraghan, J.J. ; Siew, W.H.
Author_Institution :
Strathclyde Univ., Glasgow, UK
Abstract :
For pt. I see ibid., vol.16, no.3, pp.6-12 (2000). This article is the second in the series of four related to digital signal processing to enhance partial discharge (PD) detection. In the first overview paper, several methods of removing noise from PD measurements were discussed briefly. In this paper, signal acquisition utilizing time-domain sampling, analog-to-digital (A/D) conversion (quantizing and coding), and signal reconstruction in the context of PD detection will be discussed.
Keywords :
analogue-digital conversion; insulation testing; partial discharge measurement; signal processing; analog-to-digital conversion; coding; digital signal processing; in-serve testing; insulation diagnosis; noise suppression; partial discharge detection; quantization; signal acquisition; signal reconstruction; time domain sampling; Analog-digital conversion; Circuits; Digital signal processing; Electronic equipment testing; Instruments; Insulation testing; Noise level; Partial discharges; Signal detection; Signal processing;
Journal_Title :
Electrical Insulation Magazine, IEEE