Abstract
One of the main causes of damages for wind-turbine power plants is lightning. Direct and indirect events, indeed, can produce damages and malfunctions of electrical and mechanical components. Concerning mechanical components, blades and bearings are the most involved parts. In particular, lightning damages to main-shaft bearings can result in high costs of maintenance, due to the inherent burden in the replacement of these components. The paper focuses on the modeling of wind-turbine main-shaft bearings. Two models are presented and experimentally validated: one numerical and one analytical, both conceived in a way to make the calculation of the bearing electrical impedance possible. The paper shows how these models are helpful for the design of wind-turbines lightning protection systems (LPSs). In this respect, it illustrates the criteria for the design of such an LPS and assesses the validity of design solutions by means of experimental tests.
Keywords
lightning protection; machine bearings; power generation protection; shafts; wind turbines; LPS; electrical component malfunction; lightning protection system; mechanical component malfunction; wind-turbine power plant main-shaft bearing; Bearings; lightning; lightning protection systems (LPSs); wind turbine;
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/TEMC.2010.2052462
Filename
5617264
Link To Document