DocumentCode :
136672
Title :
Review of off-line synchronous inductance measurement method for permanent magnet synchronous machines
Author :
Yuting Gao ; Ronghai Qu ; Yu Chen ; Jian Li ; Wei Xu
Author_Institution :
State Key Lab. of Adv. Electromagn. Eng. & Technol., Huazhong Univ. of Sci. & Technol., Wuhan, China
fYear :
2014
fDate :
Aug. 31 2014-Sept. 3 2014
Firstpage :
1
Lastpage :
6
Abstract :
In permanent magnet synchronous machines (PMSMs), the synchronous inductances have important influences on both steady state and dynamic performances, such as designing control strategies, predicting torque and flux-weakening capabilities. However, standard procedures for the inductance measurement have not been established yet. This paper presents a comprehensive analysis and comparative study of the various off-line methods that can be used to measure the inductances based on their accuracy, experimental setup and complexity. These approaches can be classified into three main categories: load test, DC standstill test and AC standstill test. Moreover, with the employment of finite element analysis (FEA), qualitative comparisons are done among these methods.
Keywords :
finite element analysis; inductance measurement; permanent magnet machines; synchronous machines; AC standstill test; DC standstill test; FEA; PMSM; finite element analysis; flux-weakening capabilities; load test; off-line synchronous inductance measurement method; permanent magnet synchronous machines; torque capabilities; Accuracy; Current measurement; Inductance; Inductance measurement; Rotors; Stators; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Transportation Electrification Asia-Pacific (ITEC Asia-Pacific), 2014 IEEE Conference and Expo
Conference_Location :
Beijing
Print_ISBN :
978-1-4799-4240-4
Type :
conf
DOI :
10.1109/ITEC-AP.2014.6940943