• DocumentCode
    1368499
  • Title

    Statistical evaluation of accelerated voltage endurance tests on mica insulation for rotating electrical machines

  • Author

    Wichmann, Arnold ; Grünewald, Peter

  • Author_Institution
    Siemens AG, Muelheim an der Ruhr, West Germany
  • Volume
    25
  • Issue
    2
  • fYear
    1990
  • fDate
    4/1/1990 12:00:00 AM
  • Firstpage
    319
  • Lastpage
    323
  • Abstract
    Accelerated voltage endurance testing at elevated test frequencies has been carried out. Testing of discrete populations at 50 and 500 Hz and identical field strength values yields acceleration factors between 3.4 and 22.2. However, if all populations with varying field strength values in the range from 5 to 24 kV/mm are combined and the theoretical frequency conversion factor of 10 is applied, the spread of the individual values is no greater than that obtained at a single test frequency. Each individual endurance curve lies within a 95% confidence limit of the other curves
  • Keywords
    insulation testing; life testing; machine insulation; mica; 50 Hz; 500 Hz; accelerated voltage endurance tests; acceleration factors; elevated test frequencies; endurance curves; field strength; mica insulation; rotating electrical machines; spread of individual values; statistical evaluation; Bars; Corona; Dielectrics and electrical insulation; Frequency; Insulation testing; Life estimation; Scattering; Semiconductor device testing; System testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9367
  • Type

    jour

  • DOI
    10.1109/14.52378
  • Filename
    52378