    The Feasibility of Endocardial Propagation Mapping Using Magnetic Resonance Guidance in a Swine Model, and Comparison With Standard Electroanatomic Mapping

  • Author

    Oduneye, Samuel O. ; Biswas, Labonny ; Ghate, Sudip ; Ramanan, Venkat ; Barry, Jennifer ; Laish-FarKash, Avishag ; Kadmon, Ehud ; Shwiri, Tawfiq Zeidan ; Crystal, Eugene ; Wright, Graham A.

  • Author_Institution
    Imaging Res., Sunnybrook Res. Inst., Toronto, ON, Canada
  • Volume
    31
  • Issue
    4
  • fYear
    2012
  • fDate
    4/1/2012 12:00:00 AM
  • Firstpage
    977
  • Lastpage
    983
  • Abstract
    The introduction of electroanatomic mapping (EAM) has improved the understanding of the substrate of ventricular tachycardia. EAM systems are used to delineate scar regions responsible for the arrhythmia by creating voltage or activation time maps. Previous studies have identified the benefits of creating MR-guided voltage maps; however, in some cases voltage maps may not identify regions of slow propagation that can cause the reentrant tachycardia. In this study, we obtained local activation time maps and analyzed propagation properties by performing MR-guided mapping of the porcine left ventricle while pacing from the right ventricle. Anatomical and myocardial late gadolinium enhancement images were used for catheter navigation and identification of scar regions. Our MR-guided mapping procedure showed qualitative correspondence to conventional clinical EAM systems in healthy pigs and demonstrated altered propagation in endocardial infarct models.
  • Keywords
    biomedical MRI; cardiology; image segmentation; medical disorders; medical image processing; statistical analysis; EAM system; MR-guided mapping; activation time maps; arrhythmia; endocardial infarct models; endocardial propagation mapping; magnetic resonance imaging; myocardial late gadolinium enhancement images; porcine left ventricle segmentation; reentrant tachycardia; standard electroanatomic mapping; statistical analysis; swine model; ventricular tachycardia; Animals; Catheters; Electric potential; Image segmentation; Magnetic resonance imaging; Myocardium; Navigation; Electrophysiology; image-guided treatment; magnetic resonance imaging (MRI); Analysis of Variance; Animals; Electrophysiologic Techniques, Cardiac; Feasibility Studies; Image Processing, Computer-Assisted; Magnetic Resonance Imaging; Models, Animal; Myocardial Infarction; Reproducibility of Results; Swine; Ventricular Function;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2011.2174645
  • Filename
    6069862