Dynamic Characteristics of a 22.9 kV Hybrid SFCL for Short-Circuit Test Considering a Simple Coordination of Protection System in Distribution Networks
Author :
Woo-Seok Kim ; Ok-Bae Hyun ; Chung-Ryul Park ; Seong-Woo Yim ; Seung-Duck Yu ; Seong-Eun Yang ; Hee-Sun Kim ; Hye-Rim Kim
Author_Institution :
KEPCO Res. Inst., Daejeon, South Korea
Volume :
22
Issue :
3
fYear :
2012
fDate :
6/1/2012 12:00:00 AM
Firstpage :
5601404
Lastpage :
5601404
Abstract :
This paper presents the results of short-circuit tests with a 22.9 kV hybrid superconducting fault current limiter (SFCL) on the KEPCO test grid. The hybrid SFCL we used for the test had suffered from lots of field tests including a long term operation and it is still in working order. We have already proved that the SFCL showed high reliability as well as feasibility through a long term operation and short-circuit tests performed before. In this paper, we tried to study a dynamic characteristics of the same SFCL on the distribution power grid through short-circuit tests with a circuit breaker and a reclosing relay. An artificial fault generator (AFG) was used to generate fault currents in the KEPCO power test center. The two objectives of the tests are (1) verifying a precise reaction of the SFCL to reclosing operation and (2) a study for protection coordination with SFCL. The test results showed that the SFCL worked precisely with a fast recovery of the superconducting elements when we applied a one-time reclosing operation with the interval of 0.6 second. We also suggested a proper manipulation of the coordination of the protection system in distribution networks with the SFCL in the paper.
Keywords :
power distribution protection; power distribution reliability; short-circuit currents; superconducting fault current limiters; KEPCO test grid; artificial fault generator; circuit breaker; distribution networks; distribution power grid; dynamic characteristics; hybrid SFCL; protection system; reclosing relay; reliability; short-circuit test; superconducting elements; superconducting fault current limiter; voltage 22.9 kV; Circuit breakers; Circuit faults; Delay; Fault currents; Limiting; Optical character recognition software; Superconducting transmission lines; Protection coordination; reclosing; superconducting fault current limiter;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/TASC.2011.2174950
Filename :
6070965
Link To Document :
بازگشت