DocumentCode :
1370290
Title :
Quick methods for evaluating the closed-loop poles of feedback control systems
Author :
Biernson, George
Author_Institution :
Massachusetts Institute of Technology, Cambridge, Mass.
Volume :
72
Issue :
2
fYear :
1953
fDate :
5/1/1953 12:00:00 AM
Firstpage :
53
Lastpage :
70
Abstract :
An evaluation of the closed-loop poles of a feedback control system is almost necessary if one desires an accurate knowledge of its time response. If these poles are known, the response of the system to any kind of input can be determined fairly simply. However, evaluation of the closed-loop poles has long been a stumbling block in feedback control design, because it often requires finding the roots of a polynomial of high order. In 1947 Evans1 presented the root-locus method which facilitates this evaluation, but yet is still quite cumbersome. In 1951 Kusters and Moore2 simplified Evans´ approach by utilizing generalized frequency-response plots. This paper extends this method of Kusters and Moore, and supplements it with a method for estimating by inspection approximate values of the closed-loop poles from the open-loop transfer function, and a numerical method for evaluating the closed-loop poles exactly.
Keywords :
Approximation methods; Control systems; Equations; Poles and zeros; Resonant frequency; Transforms;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
Publisher :
ieee
ISSN :
0097-2185
Type :
jour
DOI :
10.1109/TAI.1953.6371261
Filename :
6371261
Link To Document :
بازگشت