• DocumentCode
    1371583
  • Title

    Estimation of Hydropower Generator Parameters Through Field Simulations of Standard Tests

  • Author

    Lidenholm, Johan ; Lundin, Urban

  • Author_Institution
    Dept. of Power Technol., Vattenfall R&D AB, Alvkarleby, Sweden
  • Volume
    25
  • Issue
    4
  • fYear
    2010
  • Firstpage
    931
  • Lastpage
    939
  • Abstract
    Four standard test procedures-the three phase short-circuit test , the field decrement test, the slip test, and the applied voltage test-for estimation of synchronous generator parameters have been implemented in a time-stepping finite-element software. In this paper, the main features of the implementation and the postprocessing of data are described. The validity of the application is demonstrated by comparison with test results from the commissioning of a large hydropower generator. The method is shown to be effective in estimating most parameters. Better representation of the exciter and the interpole connections of the damper circuit is believed to enhance the compliance even further.
  • Keywords
    finite element analysis; hydroelectric power stations; synchronous generators; applied voltage test; field decrement test; hydropower generator; slip test; synchronous generator; three phase short-circuit test; time-stepping finite-element software; Electrical resistance measurement; Generators; Integrated circuit modeling; Rotors; Stator windings; Synchronous generators; Windings; Applied voltage tests; finite-element (FE) methods; parameter estimation; short-circuit tests; slip tests; synchronous generators;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.2010.2064776
  • Filename
    5623337