• DocumentCode
    1371691
  • Title

    Determining actual power output and derating factor of electric motors that drive oil well pumping units

  • Author

    Halderson, M. H.

  • Author_Institution
    Phillips Petroleum Company, Bartlesville, Okla.
  • Volume
    77
  • Issue
    6
  • fYear
    1959
  • Firstpage
    551
  • Lastpage
    559
  • Abstract
    ELECTRIC MOTORS that drive oil well pumping units cannot deliver an average horsepower output equal to name-plate rating without the effective or rms current exceeding rated current. Expressed another way, motors that drive pumping units must be derated if they are to operate without being thermally overloaded. A method is presented for determining the per cent of rated power output that electric motors can deliver when driving oil well pumping units. This requires a determination of average power output under actual operating conditions. A procedure for determining the average power output is developed that only requires measurements which can be made in the field by engineers and field testers.
  • Keywords
    Ammeters; Coils; Current measurement; Heating; Hysteresis motors; Wattmeters;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2185
  • Type

    jour

  • DOI
    10.1109/TAI.1959.6371498
  • Filename
    6371498