DocumentCode
1372094
Title
The life expectancy of class a random-wound motor insulation as determined by AIEE standard no. 510 test procedure
Volume
78
Issue
4
fYear
1959
Firstpage
224
Lastpage
228
Abstract
TEST PROCEDURES for determining the relative life expectancies of different insulation systems for random-wound machines, using either complete motors or models, called motorettes, are provided for by AIEE no. 510.1 The procedure calls for subjecting the motorettes to successive periods of high temperature in ovens, followed by vibration and exposure to moisture, and an overvoltage check. The cycle is repeated until the test unit fails under voltage. The tests are conducted at three or more temperatures, and are made on a sufficient number of samples to obtain the desired statistical accuracy. The tests on motors are similar, but the heating, vibration, and voltage exposures are all obtained at the same time by operating the motors on a frequent starting or reversing cycle. The results of the tests are given in the form of a life-temperature chart, as in Fig. 1.
Keywords
Fuses; Humidity; Insulation; Laboratories; Materials; Standards; Wires;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
Publisher
ieee
ISSN
0097-2185
Type
jour
DOI
10.1109/TAI.1959.6371563
Filename
6371563