DocumentCode :
1372572
Title :
Analytical-Based Partial Volume Recovery in Mouse Heart Imaging
Author :
Dumouchel, Tyler ; DeKemp, Robert A.
Author_Institution :
Dept. of Phys., Carleton Univ., Ottawa, ON, Canada
Volume :
58
Issue :
1
fYear :
2011
Firstpage :
110
Lastpage :
120
Abstract :
Positron emission tomography (PET) is a powerful imaging modality that has the ability to yield quantitative images of tracer activity. Physical phenomena such as photon scatter, photon attenuation, random coincidences and spatial resolution limit quantification potential and must be corrected to preserve the accuracy of reconstructed images. This study focuses on correcting the partial volume effects that arise in mouse heart imaging when resolution is insufficient to resolve the true tracer distribution in the myocardium. The correction algorithm is based on fitting 1D profiles through the myocardium in gated PET images to derive myocardial contours along with blood, background and myocardial activity. This information is interpolated onto a 2D grid and convolved with the tomograph´s point spread function to derive regional recovery coefficients enabling partial volume correction. The point spread function was measured by placing a line source inside a small animal PET scanner. PET simulations were created based on noise properties measured from a reconstructed PET image and on the digital MOBY phantom. The algorithm can estimate the myocardial activity to within 5% of the truth when different wall thicknesses, backgrounds and noise properties are encountered that are typical of healthy FDG mouse scans. The method also significantly improves partial volume recovery in simulated infarcted tissue. The algorithm offers a practical solution to the partial volume problem without the need for co-registered anatomic images and offers a basis for improved quantitative 3D heart imaging.
Keywords :
blood; cardiology; grid computing; image reconstruction; image registration; interpolation; medical image processing; muscle; noise; optical transfer function; positron emission tomography; 2D grid; PET; analytical-based partial volume recovery; blood; coregistered anatomic images; correction algorithm; digital MOBY phantom; image reconstruction; interpolation; mouse heart imaging; myocardial activity; myocardial contours; myocardium; noise properties; photon attenuation; photon scatter; point spread function; positron emission tomography; powerful imaging modality; random coincidences; spatial resolution limit quantification potential; tracer activity; true tracer distribution; Partial volume correction; positron emission tomograph; small animal imaging;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2010.2084589
Filename :
5624627
Link To Document :