Title :
Optimal Design of Auxiliary Teeth to Minimize Unbalanced Phase Due to End Effect of PMLSM
Author :
Jang, Ki-Bong ; Jee-Hyun Kim ; An, Ho-Jin ; Kim, Gyu-Tak
Author_Institution :
Dept. of Electr. Eng., Changwon Nat. Univ., Changwon, South Korea
fDate :
5/1/2011 12:00:00 AM
Abstract :
Discontinuity of magnetic circuit according to the end effect is generated in the PMLSM. Due to the unbalanced magnetic state, the unbalanced inductance and unbalanced back-EMF is produced. In this paper, the effects of circulating current due to the end effect are analyzed by FEA (Finite Element Analysis). By using FEA and DOE (Design of Experiment), an optimal design of the auxiliary-teeth model is carried out to decrease circulating current. And the effect of the unbalanced phase based on the auxiliary-teeth installation is considered.
Keywords :
design of experiments; end effectors; finite element analysis; linear synchronous motors; permanent magnet motors; PMLSM; auxiliary teeth; design of experiment; end effect; finite element analysis; magnetic circuit; optimal design; unbalanced back-EMF; unbalanced inductance; unbalanced phase; Coils; Current measurement; Force; Inductance; Integrated circuit modeling; Predictive models; Teeth; Auxiliary teeth; PMLSM; circulating current; end effect; thrust; unbalanced phase;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.2010.2091261