DocumentCode :
1374206
Title :
Inverter-fed drives: which motor stators are at risk?
Author :
Stone, Greg ; Campbell, Steve ; Tetreault, Serge
Author_Institution :
Iris Power Eng. of Ontario, Ont., Canada
Volume :
6
Issue :
5
fYear :
2000
Firstpage :
17
Lastpage :
22
Abstract :
This article describes measurements of the surge voltage characteristics from a number of motors driven by inverter-fed drives (IFDs). The measurements were done with both laboratory and purpose-built instrumentation. Further, we discuss why certain surges deteriorate the insulation, and we give guidelines for determining which motors may be at risk of failure from IFD voltage surges. The effect of these surges on stator windings is also included, as well as means to determine if a motor installed in a severe surge environment will fail
Keywords :
AC motor drives; invertors; machine insulation; machine testing; stators; surges; voltage measurement; insulation deterioration; inverter-fed drives; motor failure; motor stators; severe surge environment; stator windings; surge voltage characteristics measurement; Instruments; Insulation; Monitoring; Oscilloscopes; Power electronics; Pulse width modulation; Stators; Surges; Transistors; Voltage;
fLanguage :
English
Journal_Title :
Industry Applications Magazine, IEEE
Publisher :
ieee
ISSN :
1077-2618
Type :
jour
DOI :
10.1109/2943.863631