DocumentCode
1374491
Title
A Smart Health Monitoring Chair for Nonintrusive Measurement of Biological Signals
Author
Baek, Hyun Jae ; Chung, Gih Sung ; Kim, Ko Keun ; Park, Kwang Suk
Author_Institution
Grad. Program in Bioeng., Seoul Nat. Univ., Seoul, South Korea
Volume
16
Issue
1
fYear
2012
Firstpage
150
Lastpage
158
Abstract
We developed nonintrusive methods for simultaneous electrocardiogram, photoplethysmogram, and ballistocardiogram measurements that do not require direct contact between instruments and bare skin. These methods were applied to the design of a diagnostic chair for unconstrained heart rate and blood pressure monitoring purposes. Our methods were operationalized through capacitively coupled electrodes installed in the chair back that include high-input impedance amplifiers, and conductive textiles installed in the seat for capacitive driven-right-leg circuit configuration that is capable of recording electrocardiogram information through clothing. Photoplethysmograms were measured through clothing using seat mounted sensors with specially designed amplifier circuits that vary in light intensity according to clothing type. Ballistocardiograms were recorded using a film type transducer material, polyvinylidenefluoride (PVDF), which was installed beneath the seat cover. By simultaneously measuring signals, beat-to-beat heart rates could be monitored even when electrocardiograms were not recorded due to movement artifacts. Beat-to-beat blood pressure was also monitored using unconstrained measurements of pulse arrival time and other physiological parameters, and our experimental results indicated that the estimated blood pressure tended to coincide with actual blood pressure measurements. This study demonstrates the feasibility of our method and device for biological signal monitoring through clothing for unconstrained long-term daily health monitoring that does not require user awareness and is not limited by physical activity.
Keywords
amplifiers; biomedical electrodes; biomedical transducers; blood pressure measurement; electrocardiography; intelligent sensors; patient monitoring; photoplethysmography; skin; amplifier circuits; ballistocardiogram measurement; beat-to-beat blood pressure; beat-to-beat heart rate; biological signal monitoring; blood pressure measurement; blood pressure monitoring; capacitive driven-right-leg circuit configuration; capacitively coupled electrodes; clothing; conductive textiles; diagnostic chair; electrocardiogram information; film type transducer material; high-input impedance amplifiers; nonintrusive measurement; photoplethysmogram; physiological parameters; polyvinylidenefluoride; seat mounted sensors; skin; smart health monitoring chair; unconstrained heart rate; unconstrained measurement; Biomedical monitoring; Clothing; Electrocardiography; Electrodes; Heart rate; Monitoring; Sensors; Ballistocardiogram (BCG); ECG; blood pressure; chair; healthcare system; heart rate (HR); nonintrusive; photoplethysmogram (PPG); through clothing; unconstrained; Ballistocardiography; Blood Pressure; Electrocardiography; Heart Rate; Humans; Male; Monitoring, Physiologic; Photoplethysmography; Polyvinyls; Regression Analysis; Signal Processing, Computer-Assisted;
fLanguage
English
Journal_Title
Information Technology in Biomedicine, IEEE Transactions on
Publisher
ieee
ISSN
1089-7771
Type
jour
DOI
10.1109/TITB.2011.2175742
Filename
6078433
Link To Document