DocumentCode :
1375013
Title :
The influence of magnetic amplifier circuitry upon the operating hysteresis loops
Author :
Lord, Harold W.
Author_Institution :
General Electric Company, Schenectady, N. Y.
Volume :
72
Issue :
6
fYear :
1954
Firstpage :
721
Lastpage :
728
Abstract :
THE scope of this paper will be limited to the steady-state characteristics of those high-performance magnetic amplifier circuits which are classed as single-phase self-saturated types. No attempt will be made to indicate when considerations presented herein are applicable to the 100-per-cent external feedback type. Only resistive loads will be considered.
Keywords :
Force; Logic gates; Magnetic circuits; Magnetic cores; Magnetic flux; Magnetic hysteresis; Windings;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher :
ieee
ISSN :
0097-2452
Type :
jour
DOI :
10.1109/TCE.1954.6372073
Filename :
6372073
Link To Document :