• DocumentCode
    1375815
  • Title

    Saturating transformer reference circuit

  • Author

    Evans, W. G.

  • Author_Institution
    Westinghouse Electric Corporation, East Pittsburgh, Pa.
  • Volume
    73
  • Issue
    6
  • fYear
    1955
  • Firstpage
    610
  • Lastpage
    616
  • Abstract
    The theory of operation of a static magnetic reference device is described. Test results for a practical example show that an output of 15 ± 0.2 milliampere into a 50-ohm resistive load can be obtained for an input of 100 to 140 volts, 360 to 440 cycles per second, from ¿55 degrees centigrade (C) to + 100 C ambient temperature. The power input to the device is 5 watts.
  • Keywords
    Circuit faults; Equations; Limiting; Rectifiers; Resistance; Resistors; Transformer cores;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1955.6372210
  • Filename
    6372210