• DocumentCode
    1376306
  • Title

    A bidirectional load applicator for the investigation of skin response to mechanical stress

  • Author

    Sanders, Joan E. ; Garbini, Joseph L. ; Leschen, Jamie M. ; Allen, Michael S. ; Jorgensen, Jens E.

  • Author_Institution
    Center for Bioeng., Washington Univ., Seattle, WA, USA
  • Volume
    44
  • Issue
    4
  • fYear
    1997
  • fDate
    4/1/1997 12:00:00 AM
  • Firstpage
    290
  • Lastpage
    296
  • Abstract
    Instrumentation was developed to apply controlled biaxial (normal and shear) forces to the skin of a human or animal subject. The instrument mimicked any reference waveform within the constraints of a bandwidth of 15 Hz, a maximum force of 20 N, and displacement ranges of 15 mm for the normal direction and 18 mm for the shear direction. Two shaker motors, positioned with their axes parallel, were used with a low effective mass linkage and small-angle rotational joints to deliver the force. A digital feedback controller independently controlled the instantaneous normal and shear forces and recorded the resultant displacements. Evaluations on human and animal (pig) subjects demonstrated mean absolute errors between the applied and reference waveforms of less than 1.2% full-scale output for both the normal and shear directions. No degradation in performance was apparent over the course of a 1-h loading session. The instrument is to be used for the investigation of skin adaptation to mechanical stress, information that could be used to design new therapeutic methods to encourage skin load-tolerance.
  • Keywords
    biomechanics; biomedical equipment; biomedical measurement; mechanical variables measurement; skin; 1 hr; 15 Hz; 15 mm; 18 mm; amputees; animal; bidirectional load applicator; digital feedback controller; displacement range; human; low effective mass linkage; mechanical stress; normal forces; pig; pressure ulcers; reference waveform; shaker motors; shear forces; skin adaptation; skin load-tolerance; skin mechanics; skin response; small-angle rotational joints; therapeutic methods; Animals; Applicators; Bandwidth; Couplings; Effective mass; Force control; Humans; Instruments; Skin; Stress; Analog-Digital Conversion; Animals; Elasticity; Forearm; Humans; Reference Values; Skin Physiology; Stress, Mechanical; Swine; Transducers; Weight-Bearing; Wrist;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.563298
  • Filename
    563298