DocumentCode :
1377401
Title :
Standing-wave ratio of inaccessible load
Author :
Polk, Charles
Author_Institution :
University of Pennsylvania, Philadelphia, Pa.
Volume :
75
Issue :
1
fYear :
1956
fDate :
3/1/1956 12:00:00 AM
Firstpage :
9
Lastpage :
11
Abstract :
Synopsis. Formulas are given for the minimum and maximum possible voltage standing-wave ratio (VSWR) of an inaccessible load fed by an imperfect transmission line. The formulas involve measurements at the accessible input terminals of the transmission line. Required data are the VSWR existing when the line is terminated by a known, perfectly matched load and the VSWR measured when the line is terminated by the unknown load.
Keywords :
Equations; Impedance; Mathematical model; Power transmission lines; Printing; Rectifiers; Transmission line measurements;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher :
ieee
ISSN :
0097-2452
Type :
jour
DOI :
10.1109/TCE.1956.6372473