DocumentCode :
1377839
Title :
The Double 3-Phase Rectifier with Inter-Phase Reactor excited from a Frequency Tripler
Author :
Blake, L.R.
Volume :
100
Issue :
75
fYear :
1953
fDate :
6/1/1953 12:00:00 AM
Firstpage :
310
Lastpage :
314
Abstract :
The regulation curve of a double 3-phase mercury-arc rectifier is characterized by a sharp fall in the output voltage as the load current increases from zero to a value about twice that of the peak magnetizing current of the inter-phase reactor. Over this current range the mode of operation of the rectifier changes; at no load each anode fires in turn, in a manner typical of a 6-phase rectifier, but when the load current is just sufficient to magnetize the inter-phase reactor, double 3-phase operation of the rectifier commences. To reduce the no-load voltage rise, which in some rectifier applications cannot be tolerated, one of the more satisfactory methods is to excite the inter-phase reactor from an auxiliary source. It is shown in the paper that, by using a frequency tripler as a source of auxiliary excitation, a tenfold reduction is obtained both in the no-load voltage rise and in the critical load current at which double 3-phase operation commences. The variation of the rectifier no-load voltage rise with the phase and magnitude of the frequency-tripler output voltage and with the alternating supply voltage is also deduced.
Keywords :
exciters; mercury arc rectifiers;
fLanguage :
English
Journal_Title :
Proceedings of the IEE - Part II: Power Engineering
Publisher :
iet
Type :
jour
DOI :
10.1049/pi-2.1953.0109