DocumentCode :
137820
Title :
Estimation of ground surface radiation sources from dose map measured by moving dosimeter and 3D map
Author :
Minamoto, Gaku ; Takeuchi, Eijiro ; Tadokoro, S.
Author_Institution :
Grad. Sch. of Inf. Sci., Tohoku Univ., Sendai, Japan
fYear :
2014
fDate :
14-18 Sept. 2014
Firstpage :
1889
Lastpage :
1895
Abstract :
The Fukushima nuclear power plant accident that occurred in 2011 eastern Japan has created local spots with a high dose level in residential areas in eastern Japan. It is necessary to build a map of the distribution of radiation activities that shows the locations and intensities of radiation sources to assist in decontamination work. The proposed method estimates the intensities of point-like sources from the radiation dose measured by moving a dosimeter in three dimensions and 3D map of the environment, assuming that the radioactive sources are located on the ground surface. The radiation dose is measured as a few counts including a wide variability because in the proposed method, low levels of radiation are measured by moving a dosimeter. For estimating the intensities, the maximum a posteriori probability (MAP) estimation is computed on the basis of the radiation characteristics of attenuation and stochastic counts. Experiments of estimation in real environments were conducted. The experimental results showed that using the proposed method, it is possible to estimate the distributions of radiation sources using the radiation dose measured by a dosimeter and the measured 3D shape of the ground and building surface.
Keywords :
dosimetry; fission reactor accidents; radiation monitoring; radioactive pollution; 3D map; Fukushima nuclear power plant accident; attenuation counts; building surface; dosimeter; eastern Japan; ground surface radiation sources; point-like sources; radiation activities; radiation characteristics; radiation source distributions; radioactive sources; stochastic counts; Equations; Estimation; Position measurement; Robots; Semiconductor device measurement; Three-dimensional displays; Time measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Intelligent Robots and Systems (IROS 2014), 2014 IEEE/RSJ International Conference on
Conference_Location :
Chicago, IL
Type :
conf
DOI :
10.1109/IROS.2014.6942811
Filename :
6942811
Link To Document :
بازگشت