DocumentCode
1378476
Title
An inductronic double bridge
Author
Miller, J. H.
Author_Institution
Weston Electrical Instrument Corporation, Newark, N. J.
Volume
76
Issue
2
fYear
1957
fDate
5/1/1957 12:00:00 AM
Firstpage
198
Lastpage
200
Abstract
THE Kelvin or double bridge is considered as the standard type of bridge for the measurement of very low-resistance values and, more specifically, where 4-terminal resistances are used. Typical examples are in the comparison of shunts which are basically 4-terminal resistors and in the measurement of conductivity where the current terminals are at the ends of the wire or bar under consideration, and the millivolt terminals are between those current terminals.1¿3
Keywords
Accuracy; Bridge circuits; Couplings; Equations; Resistance; Resistors; Standards;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher
ieee
ISSN
0097-2452
Type
jour
DOI
10.1109/TCE.1957.6372653
Filename
6372653
Link To Document