Title :
Elimination of magnetic-amplifier control circuit inductance
Author :
Chandler, D. P. ; Downing, R. W.
Author_Institution :
North American Aviation, Inc., Downey, Calif.
Abstract :
Response of magnetic amplifiers to signal changes is typically impeded by the necessity to change the average flux linkage of the control winding in order to obtain a different output. This inductive effect requires an elapse of time during which a voltage-time integral, proportional to the required change in average flux linkage, must be applied to the control winding before a new steady-state operating point can be reached.
Keywords :
Magnetic circuits; Magnetic cores; Magnetic flux; Transient analysis; Vectors; Voltage control; Windings;
Journal_Title :
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
DOI :