DocumentCode :
1378756
Title :
Determination of the D.C./A.C. transfer error of an electrostatic voltmeter
Author :
Smith, W.E. ; Clothier, W.K.
Author_Institution :
Commonwealth Scientific and Industrial Research Organisation (CSIRO), National Standards Laboratory, Division of Electrotechnology, Sydney, Australia
Volume :
101
Issue :
83
fYear :
1954
fDate :
10/1/1954 12:00:00 AM
Firstpage :
465
Lastpage :
469
Abstract :
A method for accurately measuring the relative d.c. and a.c. sensitivities of d.c./a.c. transfer instruments is described. The method is applied to an electrostatic voltmeter whose transfer error is found to be less than one part in 10000. In the course of the measurements a sensitive method has been developed for investigating harmonic generation in non-linear filters.
Keywords :
transformer insulation; voltmeters;
fLanguage :
English
Journal_Title :
Proceedings of the IEE - Part II: Power Engineering
Publisher :
iet
Type :
jour
DOI :
10.1049/pi-2.1954.0100
Filename :
5240610
Link To Document :
بازگشت