Title : 
Fundamental Study on Removal Arsenic by Magnetic Separation
         
        
            Author : 
Nomura, N. ; Mishima, F. ; Akiyama, Yoko ; Nishijima, S.
         
        
            Author_Institution : 
Osaka Univ., Suita, Japan
         
        
        
        
        
            fDate : 
6/1/2012 12:00:00 AM
         
        
        
        
            Abstract : 
In developing countries, arsenic pollution of drinking water is a serious problem and it is required to remove the arsenic species. The targeted value of residual arsenic concentration is 50 ppb, and the processing amount is 500 L/day. The requirement for the water purification system in developing country is maintenance ability by local staff, low-cost, and simple processing system. In this study high gradient magnetic separation using magnetic seeding agent was conducted with colloidal magnetite, which realizes large-scale and high-speed processing.
         
        
            Keywords : 
arsenic; magnetic separation; purification; water treatment; arsenic pollution; arsenic removal; colloidal magnetite; drinking water; high gradient magnetic separation; magnetic seeding agent; water purification system; Magnetic domains; Magnetic flux; Magnetic separation; Saturation magnetization; Slurries; Superconducting magnets; Water pollution; Adsorption; arsenic; high gradient magnetic separation; magnetic seeding; magnetite slurry;
         
        
        
            Journal_Title : 
Applied Superconductivity, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TASC.2011.2176549