• DocumentCode
    1379267
  • Title

    Modeling study of peripheral nerve recording selectivity

  • Author

    Perez-Orive, Javier ; Durund, D.M.

  • Author_Institution
    Dept. of Biomed. Eng., Case Western Reserve Univ., Cleveland, OH, USA
  • Volume
    8
  • Issue
    3
  • fYear
    2000
  • fDate
    9/1/2000 12:00:00 AM
  • Firstpage
    320
  • Lastpage
    329
  • Abstract
    Recording of sensory information from afferent fibers can be used as feedback for the closed-loop control of neural prostheses. Clinical applications suggest that recording selectively from various nerve fascicles is important. Current nerve cuff electrodes are generally circular in shape and use a tripolar recording configuration. Preliminary experiments suggest that slowly changing the shape of the nerve to a flatter cross section can improve its selectivity. The objective of this work is to determine the effects of nerve reshaping and other cuff design parameters on the fascicular recording selectivity of a nerve cuff. A finite-element computer model of a multifasciculated nerve with different cuff electrodes was implemented to simulate the recordings. The model included the inhomogeneous and anisotropic properties of peripheral nerves. The recording selectivity was quantified with the use of a Selectivity Index. The results from the model provided information regarding the effect of using monopolar versus tripolar recording configurations, the length of the tripoles in tripolar recordings, the number of contacts that maximize the selectivity index, and the cuff length. Nerve reshaping was found to cause important recording selectivity improvements (106% average). These results provide specific criteria for the design of selectively recording nerve cuff electrodes
  • Keywords
    bioelectric potentials; finite element analysis; neurophysiology; physiological models; prosthetics; Selectivity Index; cuff design parameters; finite-element computer model; flatter cross section; inhomogeneous anisotropic properties; monopolar recording; nerve fascicles; nerve reshaping effects; peripheral nerves; recording selectivity; tripolar recording; tripolar recording configuration; Anisotropic magnetoresistance; Biosensors; Computational modeling; Electrodes; Finite element methods; Mechanical sensors; Neurofeedback; Optical fiber sensors; Prosthetics; Shape;
  • fLanguage
    English
  • Journal_Title
    Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1063-6528
  • Type

    jour

  • DOI
    10.1109/86.867874
  • Filename
    867874