• DocumentCode
    1379645
  • Title

    A scaling unit employing multi-electrode cold-cathode tubes

  • Author

    Kandiah, K.

  • Volume
    101
  • Issue
    81
  • fYear
    1954
  • fDate
    6/1/1954 12:00:00 AM
  • Firstpage
    227
  • Lastpage
    238
  • Abstract
    A complete scaling unit for counting regular or random pulses is described. The unit employs cold-cathode scaling tubes and trigger tubes in the main counting circuits. Various methods of driving cold-cathode scaling tubes are fully described. A novel method of driving the CV2271 scaling tubes is used in which the amplitudes and durations of the pulses to all stages in a cascade of these tubes are controlled directly by a common pulse generator, and cold-cathode trigger tubes are used as gating elements between the stages. A new type of pulse amplitude discriminator of high sensitivity is used at the input of the scaling unit. A simple system of marginal testing of the complete equipment is incorporated in order to obtain early indication of deterioration of tube characteristics.
  • Keywords
    cold-cathode tubes; counting circuits; gas-discharge tubes;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEE - Part II: Power Engineering
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/pi-2.1954.0051
  • Filename
    5240771