DocumentCode :
1380174
Title :
Effects of lag controllers on transient response
Author :
Ali, W. ; Burghart, J.H.
Author_Institution :
Dept. of Electr. Eng., Cleveland State Univ., OH, USA
Volume :
138
Issue :
2
fYear :
1991
fDate :
3/1/1991 12:00:00 AM
Firstpage :
119
Lastpage :
122
Abstract :
It has long been accepted that the addition of a lag controller to a linear, closed-loop system will reduce the steady-state error without appreciably affecting the transient response. Using a theoretical analysis supported by examples, the paper demonstrates that this is not the case. In fact, the settling time and the percentage overshoot will be affected significantly whenever a lag controller is used, for any system with desired settling time in the normal range
Keywords :
transient response; closed-loop system; lag controllers; percentage overshoot; settling time; steady-state error; transient response;