• DocumentCode
    1380505
  • Title

    Inductive voltage divider of simple design for 120 V and 50 Hz to 30 kHz

  • Author

    Zinkernagel, Jörn

  • Author_Institution
    Phys. Tech. Bundesanstalt, Braunschweig, Germany
  • Volume
    46
  • Issue
    5
  • fYear
    1997
  • fDate
    10/1/1997 12:00:00 AM
  • Firstpage
    1075
  • Lastpage
    1080
  • Abstract
    An inductive voltage divider (IVD) is presented, which-in spite of its simple design-meets the level of accuracy commonly needed in the field of ac-power measurement. The in-phase errors of about -(20±2) 10-6 achieved at the power frequency of 60 Hz, -(130±5) 10-6 at 4 kHz and +(70±35) 10-6 at 32 kHz can be considered adequate, considering that the determination of the power factor implies greater uncertainties at higher frequencies. The achievement is due to the build-up of the IVD using two cores, a suitable capacitance distribution and a special technique of screening which reduces the stray inductance of the windings
  • Keywords
    calibration; inductance; measurement errors; power factor; power measurement; voltage dividers; 120 V; 50 Hz to 30 kHz; IVD; ac-power measurement; capacitance distribution; in-phase errors; inductive voltage divider; power factor; screening; stray inductance; Calibration; Capacitance; Coils; Copper; Frequency measurement; Inductance; Magnetic cores; Magnetic flux; Reactive power; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.676713
  • Filename
    676713