DocumentCode :
1380860
Title :
Miniaturized current transformers for multirange operation of milliammeter ink recorders
Author :
Geyger, William A.
Author_Institution :
U. S. Naval Ordnance Laboratory, Silver Spring, Md.
Volume :
79
Issue :
6
fYear :
1961
Firstpage :
681
Lastpage :
689
Abstract :
Conventional forms of multi-range current transformers with a rated output of 5 or 10 va (volt-amperes) cannot be employed for operation of standard moving-coil milliammeter ink recorders which require about 1.5 mw (milliwatts) for full-scale deflection. Recently developed a-c and d-c types of miniaturized current transformers using cores of thin molybdenum-permalloy tape and special construction (extremely small cross-sectional area of the core and very large number of turns of the secondary winding) make multirange operation of such recorders possible.
Keywords :
Current measurement; Current transformers; Ink; Instrument transformers; Magnetic cores; Resistance; Windings;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher :
ieee
ISSN :
0097-2452
Type :
jour
DOI :
10.1109/TCE.1961.6373031
Filename :
6373031
Link To Document :