• DocumentCode
    1381206
  • Title

    An analysis of errors in the calibration of electric instruments

  • Author

    Hermach, F. L.

  • Author_Institution
    National Bureau of Standards, Washington, D. C.
  • Volume
    80
  • Issue
    2
  • fYear
    1961
  • fDate
    5/1/1961 12:00:00 AM
  • Firstpage
    90
  • Lastpage
    95
  • Abstract
    It has often been stated that the standards and equipment used to calibrate an electric instrument, or other electric measuring apparatus, should be ten times as accurate as the instrument being tested. This rule-of-thumb usually leads to impossible demands on the accuracy of the standards, particularly if more than two echelons of standards are involved. Troublesome problems should be expected in primary, secondary, and tertiary standardizing laboratories in large organizations. At any echelon, operations on a 10-to-1 basis require standards that become vastly more expensive in first cost and in actual use, because of the type of personnel and time required, than may be warranted by the instruments being tested.
  • Keywords
    Accuracy; Calibration; Instruments; Measurement uncertainty; Standards; Systematics; Uncertainty;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1961.6373080
  • Filename
    6373080