DocumentCode
1382534
Title
Some error characteristics of a data communication system
Author
Townsend, R. L.
Author_Institution
Bell Telephone Laboratories, Inc., Murray Hill, N. J.
Volume
82
Issue
1
fYear
1963
fDate
3/1/1963 12:00:00 AM
Firstpage
69
Lastpage
72
Abstract
Data recorded during the multipoint line tests which were jointly conducted by American Telephone and Telegraph and International Business Machines Corporation were studied from the point of view of attempting to determine what typical error characteristics are likely to be present during normal operation in a data communication system operating over leased line facilities. The conclusions of this study and the method by which they were reached is given. Error rates were found to be quite time variant. Statistical correlation between errors appeared to be caused by two separate mechanisms. One mechanism is a steady-state electrical noise which accounts for correlation between errors separated by times up to about 5 milliseconds. The second mechanism is a time-varying interference which accounts for correlation between errors separated by as much as several hours.
Keywords
Correlation; Data communication; Error analysis; FAA; Meteorology; Modulation; Noise;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher
ieee
ISSN
0097-2452
Type
jour
DOI
10.1109/TCE.1963.6373302
Filename
6373302