DocumentCode
1382722
Title
Field experience with gas-filled protectors on communication lines
Author
Lemieux, J.E.R.
Author_Institution
Bell Telephone Company of Canada, Montreal, Que., Canada
Volume
82
Issue
3
fYear
1963
fDate
7/1/1963 12:00:00 AM
Firstpage
441
Lastpage
448
Abstract
The Bell Telephone Company of Canada recently conducted a successful field trial of gas-filled protectors on open wire and cable intertoll facilities. The purpose of this trial, as well as extensive preliminary laboratory tests, was to compare the electrical and maintenance characteristics of gas-filled protectors with those of the conventional carbon-block spark-gap protectors. Results are summarized herein.
Keywords
Electrodes; Laboratories; Lightning; Magnetic circuits; Repeaters; Surge protection; Surges;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher
ieee
ISSN
0097-2452
Type
jour
DOI
10.1109/TCE.1963.6373332
Filename
6373332
Link To Document