• DocumentCode
    1385502
  • Title

    Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET

  • Author

    Chatziioannou, A. ; Qi, J. ; Moore, A. ; Annala, A. ; Nguyen, K. ; Leahy, R. ; Cherry, S.R.

  • Author_Institution
    Sch. of Med., California Univ., Los Angeles, CA, USA
  • Volume
    19
  • Issue
    5
  • fYear
    2000
  • fDate
    5/1/2000 12:00:00 AM
  • Firstpage
    507
  • Lastpage
    512
  • Abstract
    The authors have evaluated the performance of two three-dimensional (3-D) reconstruction algorithms with data acquired from microPET, a high resolution tomograph dedicated to small animal imaging. The first was a linear filtered-backprojection algorithm (FBP) with reprojection of the missing data, and the second was a statistical maximum a posteriori probability algorithm (MAP). The two algorithms were evaluated in terms of their resolution performance, both in phantoms and in vivo. Sixty independent realizations of a phantom simulating the brain of a baby monkey were acquired, each containing three million counts. Each of these realizations was reconstructed independently with both algorithms. The ensemble of the 60 reconstructed realizations was used to estimate the standard deviation as a measure of the noise for each reconstruction algorithm. More detail was recovered in the MAP reconstruction without an increase in noise relative to FBP. Studies in a simple cylindrical compartment phantom demonstrated improved recovery of known activity ratios with MAP. Finally, in vivo studies also demonstrated a clear improvement in spatial resolution using the MAP algorithm. The quantitative accuracy of the MAP reconstruction was also evaluated by comparison with autoradiography and direct well counting of tissue samples and was shown to be superior.
  • Keywords
    biological techniques; biology computing; brain; image reconstruction; image resolution; positron emission tomography; probability; 3-D maximum a posteriori algorithm; autoradiography; baby monkey brain; biological research technique; filtered backprojection algorithm; high-resolution animal imaging; microPET; phantoms; reconstructed realizations; reconstruction algorithm; simple cylindrical compartment phantom; Animals; Brain modeling; High-resolution imaging; Image reconstruction; Image resolution; Imaging phantoms; In vivo; Nonlinear filters; Probability; Reconstruction algorithms; Algorithms; Animals; Animals, Laboratory; Autoradiography; Brain; Haplorhini; Head; Image Processing, Computer-Assisted; Models, Theoretical; Phantoms, Imaging; Rats; Rats, Sprague-Dawley; Tomography, Emission-Computed;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.870260
  • Filename
    870260