DocumentCode :
1386112
Title :
Detection of stellate distortions in mammograms
Author :
Karssemeijer, Nico ; Brake, Guido M te
Author_Institution :
Dept. of Radiol., Univ. Hospital Nijmegen, Netherlands
Volume :
15
Issue :
5
fYear :
1996
fDate :
10/1/1996 12:00:00 AM
Firstpage :
611
Lastpage :
619
Abstract :
Malignant densities in mammograms have an irregular appearance and frequently are surrounded by a radiating pattern of linear spicules. In this paper a method is described to detect such stellate patterns. This method is based on statistical analysis of a map of pixel orientations. If an increase of pixels pointing to a region is found, this region is marked as suspicious, especially if such an increase is found in many directions. Orientations of the image intensity map are determined at each pixel using a multiscale approach. At a given scale, accurate line-based orientation estimates are obtained from the output of three-directional, second-order, Gaussian derivative operators. The orientation at the scale at which these operators have maximum response is selected. If a line-like structure is present at a given site, this method provides an estimate of the orientation of this structure, whereas in other cases the image noise will generate a random orientation. The pixel orientation map is used to construct two operators which are sensitive to radial patterns of straight lines. Combination of the output of these operators using a classifier allows for detection of stellate patterns. Different classification methods have been compared and results obtained on a common database are presented. Around 90% of the malignant cases were detected at rate of one false positive (FP) per image
Keywords :
diagnostic radiography; image classification; medical image processing; statistical analysis; breast cancer; classification methods; false positive; image noise; irregular appearance; line-like structure; linear spicules; malignant cases; malignant densities; mammograms; medical diagnostic imaging; pixel orientations map; radiating pattern; stellate distortions detection; suspicious region; three-directional second-order Gaussian derivative operators; Breast cancer; Cancer detection; Computer errors; Hospitals; Image generation; Noise generators; Pixel; Radiology; Statistical analysis; Tellurium;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.538938
Filename :
538938
Link To Document :
بازگشت