• DocumentCode
    1386115
  • Title

    Analysis of geometrical distortion and statistical variance in length, area, and volume in a linearly scanned 3-D ultrasound image

  • Author

    Cardinal, H. Neale ; Gill, Jeremy D. ; Fenster, Aaron

  • Author_Institution
    John P. Robarts Res. Inst., London, Ont., Canada
  • Volume
    19
  • Issue
    6
  • fYear
    2000
  • fDate
    6/1/2000 12:00:00 AM
  • Firstpage
    632
  • Lastpage
    651
  • Abstract
    A linearly scanned three-dimensional (3-D) ultrasound imaging system is considered. The transducer array is initially oriented along the x axis and aimed in the y direction. After being tilted by an angle θ about the x axis, and then swiveled by an angle φ about the y axis, it is translated in the z direction, in steps of size d, to acquire a series of parallel two-dimensional (2-D) images. From these, the 3-D image is reconstructed, using the nominal values of the parameters (φ, θ, d). Thus, any systematic or random errors in these, relative to their actual values (φ 0, θ 0, d 0), will respectively cause distortions or variances in length, area, and volume in the reconstructed 3-D image, relative to the 3-D object. Here, the authors analyze these effects. Compact linear approximations are derived for the relative distortions as functions of the parameter errors, and hence, for the relative variances as functions of the parameter variances. Also, exact matrix formulas for the relative distortions are derived for arbitrary values of (φ, θ, d) and (φ 0, θ 0, d 0). These were numerically compared to the linear approximations and to measurements from simulated 3-D images of a cubical object and real 3-D images of a wire phantom. In every case tested, the theory was confirmed within experimental error (0.5%).
  • Keywords
    biomedical ultrasonics; image reconstruction; medical image processing; statistical analysis; 3-D image reconstruction; compact linear approximations; exact matrix formulas; experimental error; geometrical distortion; linearly scanned 3-D ultrasound image; medical diagnostic imaging; parallel two-dimensional images series; parameter errors; relative distortions; relative variances; statistical variance; wire phantom; Analysis of variance; Distortion measurement; Image analysis; Image reconstruction; Imaging phantoms; Linear approximation; Two dimensional displays; Ultrasonic imaging; Ultrasonic transducers; Wire; Artifacts; Computer Simulation; Humans; Image Processing, Computer-Assisted; Models, Statistical; Models, Theoretical; Phantoms, Imaging; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.870670
  • Filename
    870670