DocumentCode :
1386174
Title :
Optimal image sampling schedule: a new effective way to reduce dynamic image storage space and functional image processing time
Author :
Li, Xianjin ; Feng, Dagan ; Chen, Kewei
Author_Institution :
Dept. of Comput. Sci., Sydney Univ., NSW, Australia
Volume :
15
Issue :
5
fYear :
1996
fDate :
10/1/1996 12:00:00 AM
Firstpage :
710
Lastpage :
719
Abstract :
An optimal image sampling schedule for tracer dynamic studies with positron emission tomography (PET) is proposed. This schedule incorporates the characteristics of PET measurement and uses a new cost function and the D-optimal criterion. A detailed case study of the estimation of the local cerebral metabolic rate of glucose (LCMRGLc) using the tracer fluorodeoxyglucose (FDG) and the four-parameter FDG model is presented. As the sampling schedule designed requires only four dynamic images, the storage space and data processing time are greatly reduced, while the precision of the parameter estimates is almost the same as that achieved with a commonly used schedule. The effects of intersubject and intrasubject parameter variations on parameter estimation with the use of this optimal sampling schedule are investigated by computer simulation. The simulation results show that the estimation of parameters is sufficiently robust with respect to these intersubject and intrasubject variations. The optimal sampling schedule is quite suitable therefore for PET regional parameter estimation, as well as for image-wide parameter estimation, for different subjects
Keywords :
image sampling; medical image processing; parameter estimation; positron emission tomography; PET regional parameter estimation; dynamic image storage space reduction; four-parameter model; functional image processing time reduction; glucose; image-wide parameter estimation; intersubject parameter variations; intrasubject parameter variations; local cerebral metabolic rate; medical diagnostic imaging; nuclear medicine; optimal image sampling schedule; tracer fluorodeoxyglucose; Computer simulation; Cost function; Data processing; Dynamic scheduling; Image sampling; Image storage; Parameter estimation; Positron emission tomography; Processor scheduling; Sugar;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.538948
Filename :
538948
Link To Document :
بازگشت