DocumentCode :
1386894
Title :
The absolute calibration of voltage transformers
Author :
Clothier, W.K. ; Medina, L.
Author_Institution :
Commonwealth Scientific and Industrial Research Organisation (CSIRO), National Standards Laboratory, Sydney, Australia
Volume :
104
Issue :
15
fYear :
1957
fDate :
6/1/1957 12:00:00 AM
Firstpage :
204
Lastpage :
211
Abstract :
An account is given of equipment and measuring techniques in use at the National Standards Laboratory, Australia, for calibrating voltage transformers. The equipment employs 3-terminal air-dielectric capacitors to form a voltage divider, the ratio and phase defect angle of which are determined by a self-contained build-up technique. Owing to the use of virtually loss-free capacitors, the phase angle of the divider is negligibly small. Two methods are described for calibrating transformers. In one, ratio balance is obtained by means of a small auxiliary variable-ratio voltage transformer, and phase balance by current injection into one of the detector bridge junctions. In the other method, ratio balance is provided by a variable 3-terminal air-capacitor in the low-voltage arm of the divider, and phase balance by voltage injection in series with that arm, a feedback amplifier providing a low-impedance injection circuit. In both methods the accuracy of measurement is approximately 2 parts in 105 in ratio and 0.05¿ in phase angle. The air-dielectric capacitors used in the voltage divider are tested to ensure that they have no significant voltage coefficient of capacitance or loss angle.
Keywords :
instrumentation; potential transformers;
fLanguage :
English
Journal_Title :
Proceedings of the IEE - Part A: Power Engineering
Publisher :
iet
ISSN :
0369-8882
Type :
jour
DOI :
10.1049/pi-a.1957.0049