DocumentCode :
1387173
Title :
Dynamic operation of carrier-signal-injection-based sensorless direct field-oriented AC drives
Author :
Briz, Fernando ; Diez, Alberto ; Degner, Michael W.
Author_Institution :
Dept. of Electr., Comput. & Syst. Eng., Oviedo Univ., Spain
Volume :
36
Issue :
5
fYear :
2000
Firstpage :
1360
Lastpage :
1368
Abstract :
This paper analyzes the dynamic operation of carrier-signal-based sensorless field-oriented AC motor drives. The effects of the harmonics introduced by the fundamental current transients at frequencies near the carrier-signal frequency are first analyzed, then compensation based on a fundamental current observer is proposed. The utilization of such a fundamental current observer provides the possibility of modifying the analog-to-digital conversion process to increase the number of bits effectively containing spatial information and thereby substantially increasing the accuracy of the estimated rotor position or flux angle
Keywords :
AC motor drives; compensation; control system synthesis; harmonics; machine testing; machine theory; machine vector control; observers; parameter estimation; rotors; analog-to-digital conversion; carrier-signal frequency; carrier-signal-based sensorless control; compensation; control simulation; dynamic operation; field-oriented AC motor drives; flux angle estimation; fundamental current observer; fundamental current transients; harmonics effects; rotor position estimation; Analog-digital conversion; Filtering; Frequency; Harmonic analysis; Industry Applications Society; Matched filters; Power harmonic filters; Sensorless control; Transient analysis; Voltage;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/28.871285
Filename :
871285
Link To Document :
بازگشت