• DocumentCode
    1388055
  • Title

    Current multipole expansion to estimate lateral extent of neuronal activity: a theoretical analysis

  • Author

    Nolte, Guido ; Curio, Gabriel

  • Author_Institution
    Dept. of Neurology, Freie Univ. Berlin, Germany
  • Volume
    47
  • Issue
    10
  • fYear
    2000
  • fDate
    10/1/2000 12:00:00 AM
  • Firstpage
    1347
  • Lastpage
    1355
  • Abstract
    High-resolution magnetoencephalography (MEG) allows for a detailed description of focal neuronal current sources going far beyond the dipole approximation which merely indicates the center and magnitude of neuronal activity. Higher order multipole coefficients can be related to other bulk properties, like spatial extent or curvature. The possibility and limitations of measuring spatial extent by interpreting reconstructed multipole coefficients was tested under realistic noise conditions and for model misspecifications; for this analysis the primary cortical response (“N20”) to electric median nerve stimulation was modeled by a one dimensional source distribution. The forward calculation was done analytically up to octapolar order for a spherical volume conductor. The multipole expansion is shown to estimate the lateral source extent with negligible bias; this estimate is to first-order stable against additional source features, like gyral curvature or spatial extent in a second direction (gyral depth, neuronal length). For a dipole moment of 20 nAm a lateral extent of 2 cm can be detected for a realistic noise level with large but experimentally still reasonable effort. Approximating a realistic head model by a sphere results in errors larger than the extent to be estimated; accordingly, studies on human cortical evoked responses will require multipole fitting in realistic head models
  • Keywords
    brain models; current distribution; magnetoencephalography; neurophysiology; 2 cm; MEG; current multipole expansion; electric median nerve stimulation; forward calculation; gyral curvature; higher order multipole coefficients; human cortical evoked responses; model misspecifications; multipole expansion; neuronal activity lateral extent estimation; one dimensional source distribution; realistic head model approximation; spherical volume conductor; Biomedical measurements; Brain modeling; Current distribution; Current measurement; Magnetic analysis; Magnetic field measurement; Magnetic heads; Magnetoencephalography; Nervous system; Noise level;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.871408
  • Filename
    871408