• DocumentCode
    1388929
  • Title

    Compensation for distance-dependent resolution in cardiac-perfusion SPECT: impact on uniformity of wall counts and wall thickness

  • Author

    Kohli, Vandana ; King, Michael A. ; Pan, Tin-Su ; Glick, Stephen J.

  • Author_Institution
    Dept. of Nucl. Med., Massachusetts Univ. Med. Center, Worcester, MA, USA
  • Volume
    45
  • Issue
    3
  • fYear
    1998
  • fDate
    6/1/1998 12:00:00 AM
  • Firstpage
    1104
  • Lastpage
    1110
  • Abstract
    The authors investigated the impact on the uniformity of the polar map of the maximum wall count, and on the cardiac: wall thickness of several methods used to compensate for distance dependent resolution (DDR) in cardiac perfusion imaging. Compared were: 1) filtered backprojection (FBP) reconstruction with no correction for attenuation and DDR 2) FBP with Bellini attenuation compensation (AC); 3) FBP with Bellini AC and frequency distance relationship (FDR) restoration filtering prior to reconstruction; 4) ordered-subset maximum likelihood estimation-maximization (OSEM) reconstruction with just AC; and 5) including DDR compensation and AC in OSEM reconstruction with 3D post-reconstruction Gaussian filtering. The best uniformity was obtained with OSEM reconstruction which included just AC. Nearly the same uniformity could be obtained with reconstruction by OSEM which included correction for both AC and DDR when strong 3D post-reconstruction Gaussian filtering was included. With application of this filtering OSEM with compensation for both AC and DDR achieved significantly better recovery of the original wall thickness at the expense of higher noise magnitude. For the implementations compared herein, it was noted that the modeling of AC and DDR in OSEM yielded a slightly better combination of image quality metrics than FDR restoration. Observer detection studies are needed to determine if compensation for DDR and AC does result in improved lesion detection over just compensation for AC
  • Keywords
    cardiology; haemorheology; image resolution; single photon emission computed tomography; 3D post-reconstruction Gaussian filtering; cardiac-perfusion SPECT; distance-dependent resolution compensation; improved lesion detection; medical diagnostic imaging; noise magnitude; nuclear medicine; polar map uniformity; wall counts; wall thickness; Attenuation; Filtering; Frequency estimation; Image quality; Image reconstruction; Image resolution; Image restoration; Lesions; Maximum likelihood detection; Maximum likelihood estimation;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.681986
  • Filename
    681986