DocumentCode
1389084
Title
Control of quality by discharge detection scanning during the manufacture of high-voltage plastic-insulated power cables
Author
Endacott, J.D. ; Smith, E.L.
Volume
109
Issue
3
fYear
1962
fDate
5/15/1905 12:00:00 AM
Firstpage
119
Lastpage
123
Abstract
The paper describes the design and operation of an apparatus for control of quality of extruded insulation of high-voltage polythene power cables by non-destructive detection and location of harmful electrical discharges. The apparatus scans polythene-insulated cable core at a speed comparable with that of the extrusion process of manufacture. With test voltages of up to 100 kV a.c.(r.m.s.), the sensitivity of detection is more than adequate for discrimination between harmful and harmless discharges. Discharge sites are readily located to within 3 in in cable cores of continuous lengths of more than 5000 yd. The apparatus does not require continual supervision by technical personnel.
Keywords
cables (electric); insulated wires; insulation testing; plastics;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part A: Power Engineering
Publisher
iet
ISSN
0369-8882
Type
jour
DOI
10.1049/pi-a.1962.0018
Filename
5242521
Link To Document