    Feedback regulation of hand grasp opening and contact force during stimulation of paralyzed muscle

  • Author

    Crago, Patrick E. ; Nakai, Richard J. ; Chizeck, Howard J.

  • Author_Institution
    Case Western Reserve Univ., Cleveland, OH, USA
  • Volume
    38
  • Issue
    1
  • fYear
    1991
  • Firstpage
    17
  • Lastpage
    28
  • Abstract
    A fixed-parameter, discrete-time, first-order, feedback control system is described for regulating grasp during electrical stimulation of paralyzed muscles of the hand. The stiffness of the grasp (the relationship between grasp force and grasp opening) is kept constant by linearly combining force and position feedback signals. Thus, a single continuous command signal can control the size of the grasp opening prior to object acquisition and both grasp and opening after contact. The controller achieves this change in controlled variables by scaling and summing the force and position feedback signals, rather than by a discrete switch in control strategy. Experimental tests of the control system in quadriplegic subjects show that control can be obtained over conditions ranging from unloaded position regulation is isometric force regulation as well as in the transition between these conditions. The robustness of the control system was evaluated during force regulation with isometric loads. Step response rise time and overshoot were much more dependent on system gain than on the location of the controller zero. Responses with a rise time of less than and 2 s an overshoot of less than 30% were obtained over a gain range up to 10, indicating good robustness to muscle gain reductions such as might be caused by fatigue.
  • Keywords
    biocontrol; biomechanics; feedback; muscle; patient treatment; contact force; control strategy; feedback regulation; first-order feedback control system; fixed-parameter discrete-time system; grass stiffness; hand grasp opening; paralyzed muscle stimulation; quadriplegic subjects; Contacts; Control systems; Electric variables control; Electrical stimulation; Feedback control; Force control; Force feedback; Muscles; Size control; Switches; Electric Stimulation Therapy; Feedback; Finger Joint; Hand; Humans; Isometric Contraction; Quadriplegia; Reproducibility of Results; Sensitivity and Specificity; Transducers;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.68205
  • Filename
    68205