DocumentCode :
1389642
Title :
Optimization of anode dimensions for microgap detectors at high pressure
Author :
Fraga, F.A.F. ; Marques, Ferreira R. ; Ivaniouchenkov, I. ; Margato, L.M.S. ; Goncalo, J.R. ; Policarpo, A.J.P.L. ; van Eijk, C.W.E. ; Hollander, R.W. ; Van Der Marel, J.
Author_Institution :
Dept. de Fisica, Coimbra Univ., Portugal
Volume :
45
Issue :
3
fYear :
1998
fDate :
6/1/1998 12:00:00 AM
Firstpage :
269
Lastpage :
274
Abstract :
The possibility of using microgap structures in pressurized gaseous devices for high rate synchrotron radiation detectors has been presented before; one of their main drawbacks is the limited maximum safe gain at which they can be operated. In this study we present data on the performance of microgap plates with several widths of the anodes (4 to 12 micron) and of the insulating layer (6 to 30 micron). Krypton and xenon based gaseous mixtures were used at pressures of 1, 3 and 6 bar under irradiation by 55Fe and 109Cd X-ray sources and an X-ray tube. The dependence of gain on anode voltage is analyzed, as well as the effects of drift field on gain and charge collection. We also present data on the measured safe maximum gain before breakdown versus count rate
Keywords :
amplification; anodes; ionisation chambers; Kr; X-ray; Xe; anode dimensions; anode voltage; breakdown; charge collection; count rate; drift field; gain; high pressure; microgap detectors; microgap plates; synchrotron radiation detectors; Anodes; Cathodes; Current measurement; Detectors; Gain measurement; Insulation; Pulse amplifiers; Pulse measurements; Synchrotron radiation; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.682392
Filename :
682392
Link To Document :
بازگشت