• DocumentCode
    1390022
  • Title

    Accurate determination of thermal neutron flux via cryogenic calorimetry

  • Author

    Richardson, J.M. ; Snow, W.M. ; Chowdhuri, Z. ; Greene, G.L.

  • Author_Institution
    Sci. Res. Lab. Inc., Cambridge, MA, USA
  • Volume
    45
  • Issue
    3
  • fYear
    1998
  • fDate
    6/1/1998 12:00:00 AM
  • Firstpage
    550
  • Lastpage
    555
  • Abstract
    Absolute determination of thermal neutron flux is an important capability for several applications including neutron dosimetry, analytical chemistry, oil recovery, nuclear waste clean-up, and the determination of the neutron lifetime. Few methods exist that are calibrated to better than ~0.5% accuracy. As a corollary to this statement, it is also true that few thermal neutron absorption cross sections are known to better than ~0.5% accuracy. Several groups, including one at the National Institute of Standards and Technology (NIST) have worked for many years to develop methods for pushing the accuracy below the 0.1% level. This paper describes a calorimetric technique which avoids many of the problems associated with absolute counting methods. A description of the calorimetric method and results of system tests will be presented
  • Keywords
    calorimetry; cryogenics; neutron detection; neutron flux; calorimetric method; cryogenic calorimetry; thermal neutron absorption cross sections; thermal neutron flux; Absorption; Calorimetry; Chemistry; Cryogenics; Detectors; Dosimetry; Laboratories; NIST; Neutrons; Petroleum;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.682446
  • Filename
    682446