• DocumentCode
    1390360
  • Title

    Use of Needle Track Detection to Quantify the Displacement of Stranded Seeds Following Prostate Brachytherapy

  • Author

    Lobo, Julio R. ; Moradi, Mehdi ; Chng, Nick ; Dehghan, Ehsan ; Morris, William J. ; Fichtinger, Gabor ; Salcudean, Septimiu E.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of British Columbia, Vancouver, BC, Canada
  • Volume
    31
  • Issue
    3
  • fYear
    2012
  • fDate
    3/1/2012 12:00:00 AM
  • Firstpage
    738
  • Lastpage
    748
  • Abstract
    We aim to compute the movement of permanent stranded implant brachytherapy radioactive sources (seeds) in the prostate from the planned seed distribution to the intraoperative fluoroscopic distribution, and then to the postimplant computed tomography (CT) distribution. We present a novel approach to matching the seeds in these distributions to the plan by grouping the seeds into needle tracks. First, we identify the implantation axis using a sample consensus algorithm. Then, we use a network flow algorithm to group seeds into their needle tracks. Finally, we match the needles from the three stages using both their transverse plane location and the number of seeds per needle. We validated our approach on eight clinical prostate brachytherapy cases, having a total of 871 brachytherapy seeds distributed in 193 needles. For the intraoperative and postimplant data, 99.31% and 99.41% of the seeds were correctly assigned, respectively. For both the preplan to fluoroscopic and fluoroscopic to CT registrations, 100% of the needles were correctly matched. We show that there is an average intraoperative seed displacement of 4.94 ± 2.42 mm and a further 2.97 ± 1.81 mm of postimplant movement. This information reveals several directional trends and can be used for quality control, treatment planning, and intraoperative dosimetry that fuses ultrasound and fluoroscopy.
  • Keywords
    biomedical ultrasonics; brachytherapy; computerised tomography; diagnostic radiography; dosimetry; image registration; medical image processing; quality control; fluoroscopic registration; fluoroscopy; intraoperative dosimetry; intraoperative fluoroscopic distribution; needle track detection; network flow algorithm; permanent stranded implant brachytherapy radioactive sources; planned seed distribution; postimplant computed tomography distribution; prostate brachytherapy; quality control; sample consensus algorithm; stranded seed displacement; transverse plane location; treatment planning; ultrasound; Brachytherapy; Computed tomography; Cost function; Image reconstruction; Implants; Needles; Registers; Computed-tomography (CT); X-ray fluoroscopy; minimum cost network flow; prostate brachytherapy; Algorithms; Brachytherapy; Databases, Factual; Fluoroscopy; Humans; Male; Prostatic Neoplasms; Radiographic Image Enhancement; Reproducibility of Results; Tomography, X-Ray Computed;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2011.2178254
  • Filename
    6095633