• DocumentCode
    1391703
  • Title

    Absolute calibration of a standard temperature noise source for use with s-band radiometers

  • Author

    Hughes, V.A.

  • Volume
    103
  • Issue
    11
  • fYear
    1956
  • fDate
    9/1/1956 12:00:00 AM
  • Firstpage
    669
  • Lastpage
    672
  • Abstract
    To provide a standard temperature noise source for use with S-band radiometers, the noise power from the argon discharge tube CV1881 has been calibrated at 2860 Mc/s using radiometer techniques. The absolute value of the effective temperature of the tube with a discharge current of 180 mA, when mounted across a waveguide parallel to the E-plane and properly matched, is 11 140° K (15.73 dB) with a maximum error of 260° K (0.10 dB), and represents a considerable improvement in accuracy over previous measurements. Since this tube shows a high degree of stability and consistency, it is suggested that it could be used as an absolute standard noise source for the measurement of the noise factor of receivers.
  • Keywords
    microwave measurement;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEE - Part B: Radio and Electronic Engineering
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/pi-b-1.1956.0230
  • Filename