DocumentCode
1394677
Title
Process monitoring and diagnosis: a model-based approach
Author
Dvorak, Daniel ; Kuipers, Benjamin
Author_Institution
AT&T Bell Lab., Naperville, IL, USA
Volume
6
Issue
3
fYear
1991
fDate
6/1/1991 12:00:00 AM
Firstpage
67
Lastpage
74
Abstract
A framework for process monitoring and diagnosis, called Mimic, is described. Mimic is based on the observation that the key cognitive skill for process operators is the formation of a mental model that not only accounts for current observations but also lets them predict near-term behavior as well as the effect of possible control actions. Mimic exploits three relatively new technologies: semiquantitative simulation, measurement interpretation (tracking), and model-based diagnosis. These technologies work together in a hypothesize-build-simulate-match cycle. Each of these technologies is discussed. To illustrate Mimic at work, an electric water heater modeled and tested with Mimic is considered. The advantages and limitations of Mimic, as seen by this example, are examined. Related work is discussed.<>
Keywords
computerised monitoring; expert systems; process computer control; Mimic; cognitive skill; electric water heater; hypothesize-build-simulate-match cycle; measurement interpretation; mental model; model-based approach; model-based diagnosis; process monitoring and diagnosis; process operators; semiquantitative simulation; Artificial intelligence; Decision trees; Diagnostic expert systems; Fault detection; Fault diagnosis; Humans; Integrated circuit modeling; Monitoring; Predictive models; Testing;
fLanguage
English
Journal_Title
IEEE Expert
Publisher
ieee
ISSN
0885-9000
Type
jour
DOI
10.1109/64.87688
Filename
87688
Link To Document